Circuit Breaker & Fuse Panels

QualTest & Control Inc. circuit breaker and fuse panels offer modular power with distribution flexibility.

The modular DC distribution unit is configured with a base frame and various combinations of the following modules:

  • Module 1 - Isolated six positions circuit breaker blocks. Maximum rating for each block is 300A and 100A per circuit breaker position.
  • Module 2 - Twenty-two positions GMT fuse holder board. Maximum rating for the board is 100A and 15A per GMT fuse.
  • Module 3 - Alarm board with front panel fuses and alarm LED lamps. The generic alarm board offers the following features:
    •  Cabinet intrusion alarm; audible and relay contact
    • Four sets of relay contacts; door alarm, Fuse alarm, side 1 circuit breakers alarm and side 2 circuit breakers alarm
    • Four front panel LED lamps; 1 green and 3 red

Configuration Options

Up to 18 “bullet” style circuit breakers, 3 isolated circuit breaker blocks.

  • Up to 22 GMT fuse positions, 1GMT fuse holder board.
  • Additional fan power.
  • Additional front panel LED lamps.
  • Additional relay contacts.
  • Up to 7, sixteen (16) pin wire warp front panel alarm aggregation cross connects. Custom connector is available.
  • Front access for cable / wire connection. Double lug connections for high current cables and screw terminals for fused connections.
  • Width=23”, Height=6”, Depth =5.5”
  • Maximum temperature rating: -40C to +85C


Part Number: _V_B_F-000 (Contact QualTest & Control for additional modifications / changes) 

| | | ||\Number of 16 position wire wrap cross connects (0-7)

| | | |\Total LED Lamps and Alarms for fans (0 – 9)

| | | \Additional fan (etc.) outputs (0-9)

| | \Number of GMT fuse positions (0F, 10F, 22F, or 32F)

| \Number of circuit breaker positions (0B, 6B, 12B, or 18B)

\Unit Working voltage (24V or 48V)


Fuse Distribution panel: 

  • Up to 44 fuse holders. Two, 22 positions GMT fuse holder boards are offered. Panel maximum rating is 200A- 100A per fuse board, and 15A per GMT fuse.
  • Front access for cable / wire connection. Double lug connections for input cables and screw terminals for fused connections.
  • Width=23”, Height=3.5”, Depth= 4”.
  • Fuse alarms.

Six circuit breaker panel:

  • Up to 6 “bullet” style circuit breakers. Maximum rating is 300A and 100A per circuit breaker position.
  • Front access for cable / wire connection. Double lug connections for all cables.
  • Width=6”, Height=7.5”, Depth= 7”.
  • Circuit breaker alarm.
  • Custom mounting for small cabinets (rear/side).